Upgrade your NHS Health Checks with industry leading point of care equipment
Mission Cholesterol monitoring system
On Call MultiPro HbA1c
How can point of care equipment optimise your NHS Health Checks
Using point of care testing to deliver an NHS Health Check is less costly than laboratory-led pathway
Point of care testing is more convenient for patients
Lab-led pathway offers patients three times more opportunities to miss subsequent NHS Health Check-related appointments or to exit the care pathway
Point of care offers GPs the ability to act as a ‘one stop shop’ to patients by delivering a complete NHS Health Check in a single sitting.
Does use of point-of-care testing improve cost-effectiveness of the NHS Health Check programme in the primary care setting? A cost-minimisation analysis.
Austen El-Osta et al, BMJ Volume 7, Issue 8
Mission® Cholesterol
With the Mission® Cholesterol monitoring system, you can be assured that you are getting the accuracy, reliability, and cost efficiency you need to screen patients at risk of cardiovascular disease.
The cornerstone of the NHS Health Check is a cardiovascular risk score. With the Mission analyser, you can run a full lipid panel test which in under 2 minutes, will give you Total Cholesterol, HDL, LDL, Trig – all the readings required for Q-risk.
The Mission Cholesterol monitoring system is used up and down the country by pharmacists, GP practices, PCNs and service providers to deliver rapid point of care cholesterol testing.
The Mission analyser is also the device of choice for Our Future Health, the world’s largest research study. Over a million patients have had their cholesterol measured by Mission.
Efficient
- 5-parameter lipid panel & individual tests
- Results in ≤ 2 minutes
- Sample types: whole blood, serum, plasma
Ease of use
- Portable, compact, ergonomic design
- Patient friendly
- 3 simple steps: insert strip, apply sample with a capillary transfer tube, read results
Premium Features
- Cardiac Risk Assessment
- Test devices with 18-month shelf life
- Room temperature storage
- Clinically proven accuracy
Feature | Specifications |
---|---|
Methodology | Immunoturbidimetry |
Test Time | ≤ 6 minutes/ HbA1c Test |
Specimen | 1μL capillary or venous whole blood for HbA1c Test |
HbA1c Test Range | 3.8-15.0% NGSP or 18-140 mmol/mol IFCC |
Memory | 5,500 records for patient specimens and QC tests |
Application | Only use On Call® MulitPro Test Kits and Controls |
Printer | Inner thermal printer; external printer interface |
Data Transport | RS232, USB, LAN, WLAN |
Operating Conditions | 10-40 °C (50-104 °F); 10-90% RH; Altitudes ≤ 2000m |
Screen | TFT 1024×600 touch screen |
Weight | 2.3kg without power supply and printing paper |
Dimensions | 257 x 313 x 158 mm |
On Call MultiPro
With On Call MultiPro analyser, you can deliver industry leading point of care HbA1c tests in under 6 mins. The cartridge-based system makes collecting a sample straight forward, and guarantees accurate results. There is also no need to refrigerate cartridges.
Whilst there is some regional variation in requirements, in most areas of England and HbA1c testing solution is required for a proportion of patients. The On Call MultiPro system is used up and down the country by pharmacists, GP practices, PCNs and service providers to deliver rapid point of care HbA1c testing.
The On Call MultiPro analyser is a multi-parameter machine and can also measure:
- the levels of C-reactive protein (CRP) blood to indicates whether there is inflammation,
- and the albumin-to-creatinine ratio (ACR) to help determine how well the kidneys are functioning
Efficient
- 5-parameter lipid panel & individual tests
- Results in ≤ 6 minutes
Ease of use
- Large touch screen for easy operation
- 1 uL Capillary or Venous Whole Blood
- 3 simple steps
Premium Features
- Test devices with 18-month shelf life
- Room temperature storage
- Clinically proven accuracy
Feature | Specifications |
---|---|
Methodology | Immunoturbidimetry |
Test Time | ≤ 6 minutes/ HbA1c Test |
Specimen | 1μL capillary or venous whole blood for HbA1c Test |
HbA1c Test Range | 3.8-15.0% NGSP or 18-140 mmol/mol IFCC |
Memory | 5,500 records for patient specimens and QC tests |
Application | Only use On Call® MulitPro Test Kits and Controls |
Printer | Inner thermal printer; external printer interface |
Data Transport | RS232, USB, LAN, WLAN |
Operating Conditions | 10-40 °C (50-104 °F); 10-90% RH; Altitudes ≤ 2000m |
Screen | TFT 1024×600 touch screen |
Weight | 2.3kg without power supply and printing paper |
Dimensions | 257 x 313 x 158 mm |
Conclusion:
More than 92.5% of hte results are within %5 bias (HbA1c 3.8-15.0%, 18-140 mmol/mol). Linearity R>' 0.98, 0.95<Slope<1.05, CV≤30.%
Resources
How to use the Mission System
How to use the On Call MultiPro system
Contact us
Get in touch today to find out how point of care testing can help you streamline your NHS Health Checks.